Burner model: Industrial Low-NOx-Gasburner EGLN

App­li­ca­ti­on range: Steam- and hot water boilers of all kinds, power plant tech­no­lo­gy, thermal process plants such as thermal waste tre­at­ment, indus­tri­al heat pro­duc­tion and others.

The RAY-Low-NOx-Duo­block gas burner burns all tech­ni­cal com­bus­ti­on and waste gases such as natural gas, LPG, biogas and other com­bus­ti­on gases.
10 sizes avail­able, in the capa­ci­ty range: 432 up to 18.604 kW. The gas flow rate is 43 up to 1.860 Nm3/h.This series has modu­la­ting control and is ideally suited to meet the cur­rent­ly valid NOx limits and to achieve maximum effi­ci­en­cy at the same time.

 

Table of capa­ci­ties

Burner typeBurner capa­ci­ty
in kW
Gas through­put
in Nm³/h
EGLN 150432 — 174443 — 174
EGLN 250700 — 290770 — 291
EGLN 350930 — 407093 — 407
EGLN 500975 — 581498 — 581
EGLN 6001165 — 6977117 — 698
EGLN 7001280 — 8139128 — 814
EGLN 8001400 — 9302140 — 930
EGLN 10001570 — 11628157 — 1163
EGLN 12501860 — 14535186 — 1454
EGLN 15002325 — 18604233 — 1860

Size chart (Sizes in mm)

Bren­ner­typ
EGLN
150250350500600700800100012501500
A6376376377877877871004100410041004
B1314314314429429429454454454454
B2270270270370370370390390390390
C102102102117117117274274274274
D638638638750750750900900900900